Telaire T6615 co2 Sensor Module
Specifications
Method
Dual-channel Non Dispersive Infrared (NDIR), gold plated
optics, diffusion or flow through sampling.
Measurement Range
0 to 2000 ppm
0 to 5000 ppm
0 to 10,000 ppm
0 to 50,000 ppm
Dimensions
2.25 in X 1.365 in X 0.60 in
(57.15 mm X 34.67 mm X 15.24 mm)
Accuracy*
75 ppm or 10% of reading (whichever is greater)
Temperature Dependence
0.2% FS per °C
Stability over Life of Sensor (10 Years)
< 5% of FS or <10% reading annual
Pressure Dependence
0.135% of reading per mm Hg
Response Time
< 2 minutes for 90% step change typical
Warm Up Time
• < 2 minutes (operational)
• 10 minutes (maximum accuracy)
Operating Conditions
• 32°F to 122°F (0°C to 50°C)
• 0 to 95% RH, non condensing
Storage Conditions
-40°F to 158°F (-40°C to 60°C)
(Non Condensating)
Output
Digital
UART @ 19200 Baud (Please call for detailed product
specifications).
Analog
0 to 4 VDC
Power Supply Requirements
5 VDC regulated (±5%)
Power Consumption
• 0.90 watts peak
• 0.165 watts average
Interface Connections
Designed for 12 pin male header with 0.1 in (2.54 mm)
spacing. Header not included.
Flow Rates (Via Flow Ports)
Flow through version: 50 cc/min maximum
Diffusion version: 80 - 120 cc/min
Warranty Terms
12 months